BIROn - Birkbeck Institutional Research Online

    Observations on three-dimensional measurement of confined fission track lengths in apatite using digital imagery

    Li, Q. and Gleadow, A. and Seiler, C. and Kohn, B. and Vermeesch, P. and Carter, Andrew and Hurford, A. (2018) Observations on three-dimensional measurement of confined fission track lengths in apatite using digital imagery. American Mineralogist 103 , pp. 430-440. ISSN 0003-004X.

    [img]
    Preview
    Text
    QingyangLi_6156R1_Revision_1_Gleadow.pdf - Author's Accepted Manuscript

    Download (2MB) | Preview

    Abstract

    We report the results of a comparative study to explore the usefulness of 3D measurements of confined fission track lengths (TINTs) relative to horizontal confined track length measurements (dips ≤10°), and evaluate their suitability for thermal history modeling. Confined fission track lengths were measured in 10 annealed Fish Canyon Tuff apatites containing synthetic mixtures of different length components, and two Durango apatites containing spontaneous fission tracks. Measurements were primarily carried out using a digital image-based microscope system, and they were compared to those from a regular optical drawing tube-digitizing tablet setup, and a confocal laser scanning microscope. The results indicate that 3D measurements of confined track lengths are closely comparable to conventional horizontal track measurements, and the mean track lengths of inclined (dips >10°) and horizontal (dips ≤10°) confined tracks from the one sample are equivalent within the measurement uncertainty. A strong dip-bias was observed, so that almost all the confined tracks measured were dipping at <30°, and the great majority (~70%) were dipping at ≤10°, thereby qualifying as “horizontal” confined tracks. Our results suggest that a useful increase of more than 40% in sample size can be achieved from including dip- and refraction-corrected 3D track length measurements. Some evidence was seen for a small bias in favor of shorter tracks at higher dip angles but this has very little influence on the mean lengths or length distributions up to the practical limit of dips (~30°) observed in these measurements. Results obtained using the same measurement system by a single analyst over time and between six different observers in the one laboratory show good reproducibility. These results also agree well with conventional horizontal confined track length measurements in the same samples in the second laboratory involved. We conclude that 3D measurements of confined track lengths, including both horizontal and inclined tracks, are suitable for use in current fission track annealing models derived from experiments using horizontal confined tracks.

    Metadata

    Item Type: Article
    School: Birkbeck Faculties and Schools > Faculty of Science > School of Natural Sciences
    Research Centres and Institutes: Earth and Planetary Sciences, Institute of
    Depositing User: Andy Carter
    Date Deposited: 19 Mar 2018 14:21
    Last Modified: 02 Aug 2023 17:40
    URI: https://eprints.bbk.ac.uk/id/eprint/21714

    Statistics

    Activity Overview
    6 month trend
    297Downloads
    6 month trend
    207Hits

    Additional statistics are available via IRStats2.

    Archive Staff Only (login required)

    Edit/View Item Edit/View Item