BIROn - Birkbeck Institutional Research Online

Near-field fault slip of the 2016 Vettore Mw 6.6 earthquake (Central Italy) measured using low-cost GNSS

Wilkinson, M. and McCaffrey, K.J.W and Jones, R.P. and Roberts, Gerald P. and Holdsworth, R. and Gregory, L. and Walters, R. and Wedmore, L. and Goodall, H. and Iezzi, F. (2017) Near-field fault slip of the 2016 Vettore Mw 6.6 earthquake (Central Italy) measured using low-cost GNSS. Scientific Reports 7 (4612), ISSN 2045-2322.

[img] Text
Wilkinson et al. 2017 GNSS Nature Scientific Reports.pdf - Author's Accepted Manuscript
Restricted to Repository staff only

Download (5MB)
[img]
Preview
Text
20156A.pdf - Published Version of Record
Available under License Creative Commons Attribution.

Download (1MB) | Preview

Abstract

The temporal evolution of slip on surface ruptures during an earthquake is important for assessing fault displacement, defining seismic hazard and for predicting ground motion. However, measurements of near-field surface displacement at high temporal resolution are elusive. We present a novel record of near-field co-seismic displacement, measured with 1-second temporal resolution during the 30th October 2016 Mw 6.6 Vettore earthquake (Central Italy), using low-cost Global Navigation Satellite System (GNSS) receivers located in the footwall and hangingwall of the Mt. Vettore - Mt. Bove fault system, close to new surface ruptures. We observe a clear temporal and spatial link between our near-field record and InSAR, far-field GPS data, regional measurements from the Italian Strong Motion and National Seismic networks, and field measurements of surface ruptures. Comparison of these datasets illustrates that the observed surface ruptures are the propagation of slip from depth on a surface rupturing (i.e. capable) fault array, as a direct and immediate response to the 30th October earthquake. Large near-field displacement ceased within 6-8 seconds of the origin time, implying that shaking induced gravitational processes were not the primary driving mechanism. We demonstrate that low-cost GNSS is an accurate monitoring tool when installed as custom-made, short-baseline networks.

Metadata

Item Type: Article
School: Birkbeck Faculties and Schools > Faculty of Science > School of Natural Sciences
Depositing User: Gerald Roberts
Date Deposited: 23 Oct 2017 10:27
Last Modified: 19 Jul 2025 20:04
URI: https://eprints.bbk.ac.uk/id/eprint/20156

Statistics

6 month trend
346Downloads
6 month trend
700Hits

Additional statistics are available via IRStats2.

Archive Staff Only (login required)

Edit/View Item
Edit/View Item